LCOSTA ELECTRICAL is design, install, maintain, and repair electrical systems and components in various structures, from residential homes to industrial facilities, ensuring their safe and efficient operation. Their services range from installing wiring, lighting, and backup power solutions like solar or generators, to complex infrastructure projects such as power lines and substations. These companies play a vital role in the entire electrical system lifecycle, working with architects and engineers to plan systems and providing long-term inspection, troubleshooting, and maintenance.
Require a COC from a ECB Registed Electrican. I also require a quote to correct any findings to get a Compliance certificate Please stipulate 1. Call out fee 2. Cost to issue a certificate 3. Registered with ECB 4. Availability
Hello...... - The RCCB circuit breaker on the Main switch box won't turn on with or with out any load . - When you turn the RCCB SWITCH On, it falls immediately as soon as you let the switch go with only the house lights as the only load on the switch. - When all the switches are turned off on the Main switch and nothing is plugged in (no load), the RCCB Switch trips/turns off on its own within 15 minutes. - This problem started 2 weeks ago after heavy rain fall.
Quotation for DBp-B block A *Sockets outlets (1) - 27 new 16amp dedicated 3 pin sockets, bearing the sabs mark-isolated earth pin shaved at 90°/chamfered earth. - 2x 4.0mm square (L+N) pvc wire and 2.5 mm square pvc green insulated is a wire. Both (L+N) & green wire (Length for entire units) (2) 11 new standard sockets 3 pin switch sqcket outlets bearing sabs mark (3) 40 pvc conduit 20/25mm square, each length of 80 meters Supply cables (1) from generator to DBp-B, 3 x mm square 4 core pvc /swp/pvc ecc copper cable length of 60 meters and 3x mm square 1 core earth conductor also 60 meters Breakers and isolator (1) 4 isolators with 2 pole, 63A, El 30ma. (2) 18 circuit breakers with 20A each, single polel (3) 33A x6 two pole breaker (4) 40A x2 two pole breaker (5) 20A x4 two pole breaker (6) 32A x4 two pole breaker (7) 20A x3 three pole breaker (8) A three pole breaker (9) A three pole breaker (10) 6kA (11) surge arrester x2 (12) mm square 1 core earth conductor + 2xmm square 4 core pvc/swp/ copper cable.... Extra sourse cables and breakers with cables 1 - 50 mm square 4 core pvc/swp/pvc copper cable + 35 mm square 1 core earth conductor 2- 20A x18 single pole breaker for sockets 3- A three pole breaker for kiosk 4- 10A single pole breaker int lights 5- 1/3 phase conductors x2 6- photo electric cell (pc) x 2 7- bypass switch x2 8- 20A single pole breaker + 5A single pole breaker x2 9- 10A single pole breaker x4 10- 2x2.5mm square pvc wire + 2.5mm square earth cable.. ( length for entire sockets and lights) 11- 95mm square 1 core earth conductor + mm square 4 core pvc /swp/pvc copper cable Lights and sensors with switches 1) - 6 spots light for gate entrance + 3 flood lights for gateway 2) 2x4.0mm square copper cable + 25mm square 1 core earth conductor ( length for entire gateway...) 3) - 4 surface mounted 28w /+- luman (k) LED 4) 5 of flood lights LED 81w +- lm 5)- 57 of 20w+- luman LED down lights (k) 6)- 13 of 20w+- luman LED down lights (k) with 1 hour emergency battery 7)- 24 of mm x mm 50w/+- luman (k) recessed LED light fitting 8)- 12 of mm x mm 50w/+- luman (k) recessed LED light fitting with 1 hour emergency battery 9)- 17 of mm x mm 50w/+- luman (k) surface LED lighting 10)- 3 of 1 lever 1 way light switch 11)- 3 of photo electric cell 12)- 29 of occupancy sensors... 13)- cable tray mm length for entire supply cables 14) - 26 data points 15)- new tier compartment pvc power skirting unknown length..
I would like to be assisted with COC for 45 m2 2 bedroom flat
Selling the house
The current condition of the property is that it was previously vandalized, and parts of the electrical supply were damaged or disconnected. We require assistance with restoring all electrical connections, ensuring the circuits are fully functional, and obtaining a valid Electrical Certificate of Compliance. This is the overall summary of the work needed.
I am installing a new aircon unit and need an electrical point to the unit. The DB box very close to the insulation area it’s In fact the wall next to the DB board on the outside. Please give me a quote. DB board indicated on floor plan in red box and new aircon unit compressor to be installed at green box on floor plan.
I need an Electrical COC for my flat, as I have sold it.
Assistance with electric stove connection and lights that are not lighting. The geyser that is leaking while on.