20m from manhole to furtherest gulley. Was told sewer has collapsed. Blockage still there. Plumber tried to use drain spring cleaning machine. 20m of mm sewer pipe Three gulley points and three toilet points. To dig new trench possible removal of old sewerpipe or to lay new pipe to manhole.
Ø PVC Soil and Vent Pipe 6m, Ø 50 PVC Soil and Vent Pipe 6m, x 55 x 95° PVC CE Anti-Syphon Horn Bend, x 50 PVC Eccentric Reducer, x 50 x 95° PVC PL Junction, x 95° PVC CE Junction, Ø PVC Holderbat, 50 x 95° PVC PL Junction, 50 x 95° PVC CE Junction, 50 x 95° PVC PL Bend, 50 x 95° PVC CE Bend, 50 x ° Bend, Ø 50 PVC Holderbat and PVC lubricant Soft
Need to re wire 2 bedrooms, Launch, kitchen & Bathroom with 2 outside rooms, Bathroom & Garage. The house was an one room RDP house & it eas extended in . Ever since it was extended, electricity appliences,TV, four & Two plates stoves, fridge lights are getting damaged..In the Plasma TV & Dstv decoder where strucl by lighting & our is the only house that was struck by lighting that day. Our phone chargers & laptop chargers dont last. We are constantly repairing our electrical appliences because they aleays get burned.
When switching the geyser on it trap mainshwitch ( electricity)
I would like to have the faucets in my bathroom replaced. Currently they are two separate faucets. I am flexible to keeping them separate or combining them into one. I do not have the parts myself and would like to be advised whether the faucets can be prov8ded or if I should get them myself for installation.
The dwelling consists partly of the original timber framed & clad unit possibly constructed years ago plus 's extensions providing two enlarged bathroom, two additional bedrooms and kitchen. The existing legacy installation requires to be tested for safety/compliance. Earth resistance of a socket outlet circuit in the original timber frame & clad building is unacceptably high. Installation consists largely of conductors in steel conduit which is employed as the earth return. Some wiring consists of twin & earth cable possibly installed during the 's. The dwelling consists of lounge/dining room, three bedrooms, kitchen, bathroom, shower room & garage where a more recent DB has been installed. The property is rented to tenants.
We are staying now for two years at the place. In these two years the wall on the other side of shower and Linen cupboard are constantly wet. Either the tiles were laid down without waterproofing. We just suspect a quick fix was done before we moved in. We would want to find out where the leakage is. And how much to fix or to put in a bath in the place of the shower.
I need a municipal electrical cable joined/ fixed. CoCT has determined there is a problem and provided me with a temorary emergency cable. The problem is under the tarred driveway according to them. See X on photo. Company must also be able to fill and retar after the work is completed or refer me to someone who can.
Remove existing light fittings and old cables. Supply and installation of 1.5mm black round cable for light fittings. Supply and Install 2.5mm cable for the plugs including double compartment power skirting (plugs). Supply and installation of 3 pir wall motion sensors. Supply and installation 10 LED x light fittings. Label DB accordingly.