Installation of new additional sewer line as per building plan to main sewer connection and Reroute part of existing sewer line to main sewer connection. 2. Installation of one new heat pump for 2 geysers including: - Relocating 1 existing geyser - installing a new 2nd geyser 3. New installation as per building plan of: 3/4 inch water supply pipes from geyser to points and drainage from points to sewer line for 2 new built bathrooms, 3 existing bathrooms and new built kitchen, and installation of new sanitary fittings 4. Installation of new mentis drain on driveway in front of double garage
Knowledgeable person to come and do site inspection. New extension (36 m) from existing electric fence is required to be installed on top of newly installed palisade fence, with gate on street front. Connection is to be from existing energizer. Repair one or two broken earthing pegs. Assess the general condition of existing segments of electric fence. Provide a quote that specifies cost items and labour. It would be greatly appreciated.
Five room with double garage and bathroom kitchen with two separate single plung and sitting room with two separate single plung the other three rooms each with single plung ten outside lights one plung in garage and bathroom and isolator for stove eah room with single switch and two passage switch and light in veranda
I have a section of the roof that is flat. There is a hollow depression in the roof where water collects when it rains and it eventually seeps through or floods in through an adjacent skylight. the depression must be removed and resealed. There is water ingress through a chimney that was retro fitted, which needs to be repaired.
1 I need to renovate my bathroom, all the sanitary ware is to be replaced as it is old and an undesirable colour. (Sink & faucet, Toilet, Bathtub with taps) 2 There is also a kitchen sink that needs to be replaced, and two taps for laundry that needs to be lowered slightly (20cm downwards). in the same position but just a bit lower so that the taps are underneath the kitchen counter.
Old roof sheeting is rusting, some sheets are almost rusted through. will need to replace the roof sheets with galvanized iron sheeting. area is aprox. 4.5m x 3.5m. Need a quote for 1) take off and remove old sheeting labour cost, 2) labour cost for putting up the new sheets, 3) quote should include cost of material as well (galvanized sheets, screws, washers etc.)
I have a litres of jojo slimline tank . I wanna connect water from the main water supply into jojo and from jojo into the house. I don’t know if the same pressure pump that is currently connected will work or should I buy one. I need a job to be done by professionals/ you don’t wanna take chances. So I need to know how much can be expected from me for the job to be done.
The thatched roofing will be used on a lodge with gumpole structure. The size on plan = 78m2 On a slope of 45 degrees = m2 I'm looking for a square meter rate that will be applicable for other units as well. Rate should include the thatch covering, the gumpole roofing structure as well as the gumpole columns.
Garage roof is rusted through in spots, leading to water leaking through, damaging garage wall and door (see pics). Part or all of the garage roof may need replacement. Original roof is galvanised mild steel. Floor size of garage is 32m2, so roof is slightly larger than that. Roof is only slightly sloped (see pic).
Quote due by Latest 12:00 Thursday 13th May Bill of quantities: PROFILED METAL SHEETING AND ACCESSORIES 0,58mm Thick "Brownbuilt" metal sections, Klip Lok , "Galvanised AZ " roof sheeting colour "Lime white" C1S. Sheeting and accessories fixed to steel structure with galvanised "KL " clips to manufacturer's specifications including sealing strips to laps and seam stitching A Roof covering with pitches not exceeding 25 degrees and with side laps seam stitched m2 29 B Rolled edges at verge m 30 C Cover flashings mm girth m 17 D Counter flashings mm girth m 37 E Side wall flashings mm girth m 3 F Head wall flashings mm girth m 51 G mm x mm Standard fascia gutters fixed to roof sheeting with and including clips m 30 H Extra over for angle No 10 I Extra over for outlet with nozzle for and jointing to x mm diameter rainwater pipe including domical grating No 5