We need advice on what needs to be done to obtain a COC. It is a farm / rural/ setting. We then need a COC to be issued when compliant as well, We were also advised to rather remove unnecessary items like pumps for water fountains, "pretty stoep lights" and self installed leads etc. The are three Eskom low amp boxes on the property that feeds each building
Waterproofing to the balcony: Aluminum doors will be removed to the balcony Aluminum doors and frames will be wrapped in bubble wrap and stored in the garage for safekeeping until re-installation. All cement and waterproofing layers will be chopped up and removed off-site from the balcony. Rubble skip will be on-site and removed once it is filled. All existing waterproofing will be removed. mm Turn-ups will be chopped off in order to apply the waterproofing application onto the bricks. Existing outlets will be removed. New 63mm Flange outlets will be fitted to the parapet walls to allow water to discharge outside of the balcony. Screed-to-fall will be done to ensure water runs out of the outlets, and that there will be no water ponding in any areas. 50x75mm Angle will be fitted where the door will be fitted to prevent water from running back into the rooms. The waterproofing application will consist of the following: x2 Coats of Mapei-Lastic Mapei-tape to all turn-ups and corners and into the cavities. Mapei-net the flat surface x1 coat will be applied, followed by the Mapei-net and Mapei-tape being applied on top of the 1st coat. 2nd coat will be applied over all of the above-mentioned after 24 hours. Aluminum doors and frames will be re-fitted. Turn-ups and bands around the frames will be plastered to a smooth finish. Waterproofing application and plaster will be left for x3 days before the painting and tiling can commence. New tiles will be installed.
Hi Please email me the following information. May not always be available on my phone. I need to know price point per fixed location property. It is for my uncle's gym. I need to know how many call outs I get get for one site. I believe your industry refers to it as the utilisation allowance. Is there any out of bundle pricing? Regards
Waterproofing to the balcony: Aluminum doors will be removed to the balcony. Aluminum doors and frames will be wrapped in bubble wrap and stored in the garage for safekeeping until re-installation. All cement and waterproofing layers will be chopped up and removed off-site from the balcony. Rubble skip will be on-site and removed once it is filled. All existing waterproofing will be removed. mm Turn-ups will be chopped off in order to apply the waterproofing application onto the bricks. Existing outlets will be removed. New 63mm Flange outlets will be fitted to the parapet walls to allow water to discharge outside of the balcony. Screed-to-fall will be done to ensure water runs out of the outlets, and that there will be no water ponding in any areas. 50x75mm Angle will be fitted where the door will be fitted to prevent water from running back into the rooms. The waterproofing application will consist of the following: x2 Coats of Mapei-Lastic Mapei-tape to all turn-ups and corners and into the cavities. Mapei-net the flat surface x1 coat will be applied, followed by the Mapei-net and Mapei-tape being applied on top of the 1st coat. 2nd coat will be applied over all of the above-mentioned after 24 hours. Aluminum doors and frames will be re-fitted. Turn-ups and bands around the frames will be plastered to a smooth finish. Waterproofing application and plaster will be left for x3 days before the painting and tiling can commence. New tiles will be installed.
Good day Sir / Madam I trust this email finds you well. We are kindly requesting you guys come and do a site inspection at 90 Bekker Road, Vorna Valley Building A, Hertford Office Park, Midrand ( Do advise when you can come through) on the following request, • 5 Red plugs with 5 external multiplugs • The plugs must be round on the LIVE POINT ( not a half hole please ) • The plugs will be mounted on the poles and external multiplugs can be connected externally there ( picture attached ) The quote must include the following: • Labour rates ( For after-hours) • Show us a consumable explanation of the reg plugs in terms of power usage • installation costs (Including Cabling on walls and desk to the Genset)
Please I would like to have a quotation of a building that has a floor and ceiling that is damaged because of an air handling unit that is placed on top of timber floor. The ceiling below that floor is also affected. Please I would like to have the following in the quotation: 1. An investigation on the cause and extend of the water damage on the floor/ceiling. 2. On top of the timber floor there is a torch-on waterproof. What is the rate of the waterproof when it is removed and when it is replaced with new. Thank you. Kind regards,
Looking for a home alarm system to be installed in my new home . 3 doors/entrances Home is sqm With mobile access to system Possible add on of cctv cameras to cover the perimeter of home (erf sqm) (4-6 external cameras) ( 2 internal cameras ) Preferably its own power supply to run during loadshedding etc .
We require a quote for an armed bodyguard to accompany our technician whenever they attend to a callout in Khayalitsha MyCiTi bus kiosk known as Kuyasa Kiosk, this would be on a sporadic basis, maybe 3 to 4 hours once every approximately 2 weeks for the next 2 years. the rate would therefore need to be an hourly rate and would be for whoever would be available when the call comes through.
1) Need to heighten existing asbestos-cement fence to fill a gap were 3 burglaries took place over x-mas season. 2) Would also need 3- 5 support poles -circa 3.5 meters. 3) Kindly supply standard width of your metal fence AS WELL AS Palisade fencing and pole prices - No decision yet as which of above two is more secure to intruders PLEASE NOTE - my phone ONLY rings for direct incoming calls - NOT Text or Voice Messages - Kindly ask your agents to PHONE .
It is a double story renovation from rental to a bed and breakfast. There is four to 5 plugs per room, every room has an en-suite bath/shower. It is 11 bedrooms, kitchen, dining area, Reception area, 2x linen rooms, each floor has its own DB, earthing required, outside lights working with a day/night switch, 2x geysers, 1 stove