1. Clean down and prepare internal smooth walls and add one coat PVA paint sqm 2. Clean down and prepare internal smooth walls and one coat eggshell enamel paint sqm 3. Clean down and prepare gutters and downpipes and one coat acrylic PVA paint 27m 4. Clean down and prepare ceiling and one coat exterior 28sqm 5. Clean down and prepare door frames and one coat gloss enamel paint25sqm
We had water damage at the office and the existing laminated floor was flooded. We need a quotation for insurance purposes and should the claim be approved, then the supplier must also be prepared to do the installation, please. The quote as soon as possible, please and the installation also to be scheduled soon after the insurance approved the quote.
IRB waterproofing quote needed. Greetings to whom it may concern, I have a house with part of the roof being flat. The problem initially was the gutter connectors are to small for a large amount of water. Subsequently outlet avenues were made available as to alleviate the water buildup. I have had work done on the roof and recently had an assessor from outsurence asses the roof His recommendation is that a thorough waterproofing needs to be done as the waterproofing done last year is flaking and allowing some water to seep through. This needs to be sorted out and would request an assessment and quote in this regards.
Good day, I want to fully repaint my interior of my house. Work that needs to be done: All the walls - Living room - 2 bedrooms - 2 bathrooms - Skurting - Ceiling of 1 bathroom. - Kitchen cupboard - 2 doors - Window frames The house floor sqm is 99 I would estimate the walls to be around - sqm.
So just some notes to guide you through the attachments. A - Confirmed small block parquet floor as per foto (Might be a block or two missing) B - The owner can not remember if there were parquet floor, its been 40 years... Her son say that there might be, but not % sure. C - There is only carpet on top of the concrete, we would like to know if there is a product that we can use that might tie into the parquet look for this area. I think the full floor area of the confirmed space is about : 44 square meters The un confirmed space is about : 37 square meters TV room and study is about : 16 square meters 1st quote: Restore of the confirmed area. (Including the lifting of the carpet, since I might break the floor even more) 2nd quote: Restore of the total confirmed and un confirmed area (Including the lifting of the carpet, since I might break the floor even more) 3rd quote: A suitable option that would tie in with the parquet floor look.
I require interior of home to be painted... Avg 3x bedroom (+/- 15sqm)....1* kitchen.... Dining room, hallway, balastrades, entrance hall, lounge and study. 1* central bathroom All walls, trim, cornice, ceiling, skirting, door frames, doors. As an extra option, varnish to all window and frames +/- 1 per room (2*1.5m)
Its a change house for mine workers specifification is as follows: One coat acrylic PVA or emulsion paint 1.On internal plastered walls .3m2 Clean and paint 2coats plascon super enamel 1.On door frames 3.0m2 2.On windows frames and burglar bars 7.0m2 One coat wood primer, two coats varnjsh 1.On woodendoors 23.6m2 Clean down and paint one Plascon Galvogdip metal primer and two coats 1.On steel doors 28m2 Quote must include supply ,delivery ,and labour
I have an open balcony on top of a concrete slab. Under the balcony is my scullery as well as a bedroom. Between the tiled floor and the wall around the balcony, water is leaking into the scullery and bedroom. The leaks are only just where the roof and the wall meets, not any other places on the roof. In the corner of the bedroom you can also see the damp on the wall, just opposite the one outlet of the water on the balcony.
Specification: Waterproofing to concrete retaining walls to be one layer Derbigum CG4 waterproofing membrane, with mm side laps and mm end laps, sealed to primed surfaces by means of 'torch-fusion', to receive Delta MS8 Delta MS8 preformed high density polyethylene dimpled drainage and protection layer to receive compacted fill, to engineers specification, on top of geo drainage pipe system as per engineer's specification. Waterproofing to be installed by an Approved Derbigum Contractor under a 10-year guarantee. Dimple drain to receive a cover flashing to protect waterproofing membrane from stone falling between waterproofing membrane and dimple drain during compaction and construction
The bathroom, laundry & garage had been added to the existing house and sone time after the initial build, the corrugated roof of this new structure (which includes these 3 areas) was raised. When it rains, it leaks into the old structure on one side (that we are aware of) where the old and new structures meet..